Sign in
Explore Insights and Innovations in Mechanical Engineering through Guest Blogging
Explore Insights and Innovations in Mechanical Engineering through Guest Blogging
Your Position: Home - Valves - Valve Types with Their Advantages and Disadvantages
Guest Posts

Valve Types with Their Advantages and Disadvantages

Sep. 09, 2024

Valve Types with Their Advantages and Disadvantages

A butterfly valve is a quarter-turn valve used to regulate the passage of fluids through a pipe. Some level of control is also provided to the fluid. The design is such that complete flow is provided but with a set amount of efficiency. You cannot get positive shut-off from butterfly valves. But now it&#;s possible to build butterfly valves with tight closure thanks to high-temperature ratings and the latest polymers.

Click here to get more.

Several components of a butterfly valve include a metallic disc or butterfly disc, an outer body/casing, an actuator, and a positioning plate. A strong seal is made due to the packing. This seal surrounds the stem and protects the stem. The disc is mounted on a rod and stops fluid passing when the valve is closed.

The disc moves depending on the opening or closing of the valve. When the disc rotates perpendicular, the valve is entirely open, and a large amount of fluid can pass through the pipe. A seat is also fixed on the body. This seat gives a proper seal to the body. Most manufacturers provide an additional seal in case the seat gets damaged.

Butterfly Valves Advantages

Butterfly valves are widely used for several reasons. Some advantages of check valves are as follows:

  • Butterfly valves are lightweight with a wafer-form body. The low weight and compact size make them favourable for use in many applications.
  • Butterfly valves are relatively cheaper than other valves. This may be because of the low weight and that a small number of components are used in their construction.
  • The installation costs are low.
  • The design is not complicated. A small number of parts are used in the construction of butterfly valves.
  • It is reasonably convenient and easy to repair butterfly valves. So we can say they are maintenance-friendly.
  • Butterfly valves can transfer mud with a little fluid deposit in the outlet of the pipe.

Butterfly Valves Disadvantages

There are a few disadvantages of using butterfly valves. They are discussed below:

  • A part of the butterfly disc is always facing the flow even if it&#;s completely open. So there&#;s still a pressure switch over the valve no matter what the setting is.
  • The sealing is not as good as other valves.
  • When butterfly valves are used, throttling is limited to low-pressure drop systems.
  • Sometimes, the choked flow may occur when using a butterfly valve.

How to choose the right check valve?

Tilting disc, slanted seat check valves

The slanted seat check valve also offers enhanced resistance to water hammer. The valve has a double eccentric shaft position as well as an increased seating angle. This yields a shorter valve stroke, thus reducing the time taken for the door to close.

Hydraulic dampers are recommended, especially when the valves are installed on a pumping station where high frequency opening and closing of the valve is required. The valve disc closes quickly over the first 85% of its angular travel before meeting the hydraulic damper. The damper then dissipates the kinetic energy of the disc and forces it to open slightly. The disc closes until it contacts the damper again and this cushions the disc until it returns to its fully closed position, sealing the valve. This function greatly reduces the onset of water hammer due to the damped and controlled method of valve closure. 

Hydraulic dampers are recommended, especially when the valves are installed on a pumping station where high frequency opening and closing of the valve is required. The valve disc closes quickly over the first 85% of its angular travel before meeting the hydraulic damper. The damper then dissipates the kinetic energy of the disc and forces it to open slightly. The disc closes until it contacts the damper again and this cushions the disc until it returns to its fully closed position, sealing the valve. This function greatly reduces the onset of water hammer due to the damped and controlled method of valve closure.

For more details, please see our slanted seat check valve product information.

Nozzle check valves

Nozzle check valves are designed with the valve disc connected to the stem which is guided on the central horizontal axis. A spring is positioned between the disc and the diffuser sleeve. When flow enters the valve, the hydraulic force exerted onto the front face reacts against the spring, causing the spring to compress and allow the valve to open. When the flow stops, the spring forces the disc to return to the closed position.

Due to the spring-assisted closure and the short linear valve stroke, the nozzle check valve is one of the quickest acting check valves available and is commonly used in pumped systems where water hammer is a potential concern. Because the disc is constantly in the direct line of flow, the head loss characteristics of this valve are higher compared to that of conventional swing check valves.

Link to Yaxing Valve

Related links:
Double Block-and-Bleed and Double Isolation-and-Bleed
What is lost wax casting?

For more details, please see our nozzle check valve product information.

What to consider when choosing your check valves?

In order to choose the right check valve for your application, several selection criteria should be considered. First, however, there is not one type of check valves being the best choice for all applications, and the selection criteria may not be equally important for all cases. Some of the things you may need to consider are fluid compatibility, flow characteristics, head loss, non-slam characteristics and total cost of ownership.

Fluid

All check valves referred to in this article are designed for water and treated wastewater applications, but using the valves for raw wastewater/sewage applications may cause some issues. When selecting a valve for these fluids, you should consider how the presence of solids may potentially affect operation of the valve.

Flow characteristics

If a check valve closes very fast, it may prevent slamming against upstream equipment such as pumps. However, the rapid closure will not protect against the surges caused by pumps being started and shut down. If the valve opens (and closes) quickly, the flow will change rapidly and thus increase likeliness of surge occurrence.

Head loss

Head loss is, among other things, a function of fluid velocity. The head loss through a valve is determined by the internal design of the valve and the opening degree. When a valve is designed with a restricted (narrowed) opening compared to the pipeline, the velocity will increase through the valve, increasing the head loss as a result. Vice versa, if a valve is designed with less restriction and bore is equal size to the pipeline, the head loss will be smaller, and the valve will in practice not affect the overall head loss of the system. There are a number of values for head loss, amongst others zeta values, Kv and Kvs values.

Total cost of ownership

The costs for your check valve consist of more than just the purchase price. For some installations, the most important costs may be purchasing and installation, but in other cases, maintenance or energy costs may be equally or even more important. Also protecting more valuable equipment such as e.g. pumps has to be considered, and looking at the valve performance will be crucial. When considering costs as a selection criterion for your check valve, the total costs over the life of the valve should be considered. In general, the simpler the valve construction is, the lower are the maintenance requirements. The higher the Kv value, the lower the energy consumption. The higher the performance, the better the protection ability.

Non-slam characteristics

Check valve slam can affect pressure surges in a negative way. First step of the process is when the pump stops, starting the pressure surge. Second step is, when the flow is reversed, slamming against the fully closed check valve. If the check valve closes too fast, the kinetic energy is turned into high pressure, stressing the pipes, and causing high noise.

A slam sounds like if the disc or the ball from the check valve is hitting the seat and can make quite some noise. However, the sound is not caused by the physical closing but by a sound wave arising from a pressure spike stretching the pipe wall.

To prevent the occurrence of check valve slam, the valve should close in a controlled way and slower when near closed position. For a check valve to close slowly, it requires additional ancillary equipment, such as hydraulic dampers, which act as a cushion to the valve door, as it comes into its seated position. This slower closure allows the fluid to pass through the check valve until it closes, causing less kinetic energy turning into high pressure, and thus less energy to feed and maintain the surge. Consideration must be given to the upstream pump to ensure that it is suitable for reverse spin and flow.

As swing check valves have the disc in the flow stream, helping with rapid closure, they have better non-slam characteristics. However, today many pumps are frequency converted, enabling them to adjust the start-up and closure time to avoid water hammer.

Want more information on What are Check Valves? Feel free to contact us.

Comments

0 of 2000 characters used

All Comments (0)
Get in Touch

Copyright © 2020 Wordblogger.net

  |   Minerals & Metallurgy   |   Toys & Hobbies   |   Timepieces, Jewelry, Eyewear   |   Textiles & Leather Products   |   Telecommunications   |   Shoes & Accessories   |   Service Equipment   |   Security & Protection   |   Rubber & Plastics